banner
GENPLUS POWER SOLUTIONS

GST : 03EYQPS9812G1ZW

30 KVA SINGLE PHASE
30 KVA SINGLE PHASE

30 KVA SINGLE PHASE

Price 496000.00 INR/ Set

MOQ : 1 Piece

30 KVA SINGLE PHASE Specification

  • Engine Type
  • 4 Stroke, Inline
  • Dimension (L*W*H)
  • 2200 mm x 1000 mm x 1320 mm
  • Standard
  • CPCB IV+
  • Engine Model
  • TATA Motors Oil Cooled
  • Protection Class
  • IP23
  • Fuel Consumption
  • Approx. 6-7 litres/hour at full load
  • Insulation
  • Class H
  • Bore *Stroke
  • 97 mm x 128 mm
  • Alternator
  • Brushless, Synchronous
  • Poles Number
  • 4
  • Fuel Tank Capacity
  • 60 Litres
  • Product Type
  • 30 KVA SINGLE PHASE DG SET
  • Output Type
  • Single Phase AC
  • Rated Power
  • 30 KVA
  • Rated Voltage
  • 230V
  • Starting Type
  • Electric Start
  • Rated Frequency
  • 50 Hz
  • Power Range
  • 30 KVA
  • Color
  • Blue
  • Cooling System
  • Water Cooled
  • Noise Level
  • Silent (Acoustic Canopy)
  • Phase
  • Single Phase
  • Speed
  • 1500 RPM
  • Weight
  • Approx. 950 kg
  • Control Panel
  • Auto/Manual Control Panel with AMF facility
  • Compliance
  • Meets latest CPCB IV+ emission norms
  • Lubrication System
  • Forced Lubrication
  • Display
  • Digital Meter- displays Voltage, Current, Frequency, and Hour Meter
  • Exhaust System
  • Industrial Grade with rain cap
  • Fuel Type
  • Diesel
  • Regulation
  • Voltage Regulation +/-1%
  • Application
  • Commercial, Industrial, Emergency Backup
  • Enclosure Type
  • Weather and soundproof acoustic enclosure
  • Battery Capacity
  • 12V, 88Ah
 

30 KVA SINGLE PHASE Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Delivery Time
  • 1 Week
 

30 KVA SINGLE PHASE About

Tata Motors Gensets Reliable Power for Every Need

Tata Motors Gensets are engineered to deliver reliable, fuel-efficient, and high-performance power solutions for residential, commercial, industrial, and institutional applications. Built with advanced technology and designed to perform in demanding conditions, Tata Motors Gensets ensure uninterrupted power with low operating costs and dependable performance.



Advanced Control With AMF Panel

Switch between automatic and manual generator control seamlessly with the integrated Auto/Manual Control Panel. The built-in AMF (Auto Mains Failure) facility automatically detects power outages, starting and shutting down the generator as needed, ensuring a continuous supply without manual intervention.


Optimal Performance and Monitoring

Equipped with a digital meter displaying voltage, current, frequency, and hour readings, monitoring your generator's performance is straightforward. With a rated power of 30 KVA, 230V output, and tight voltage regulation (+/-1%), it delivers stable, reliable power matching industrial and commercial needs.


Robust and Silent Operation

Encased in a weatherproof, acoustic canopy, the generator ensures silent operation and protects internal components from harsh environmental factors. The forced lubrication and water-cooling systems enhance engine life while maintaining steady performance, even during continuous operation.

FAQ's of 30 KVA SINGLE PHASE:


Q: How does the auto/manual control panel with AMF benefit emergency backup situations?

A: The auto/manual control panel with AMF (Auto Mains Failure) automatically detects main power failures and starts the generator instantly, ensuring your operations remain uninterrupted without manual intervention. This feature provides peace of mind, especially during unexpected outages.

Q: What types of applications is the 30 KVA Single Phase generator best suited for?

A: This generator is ideal for commercial, industrial, and emergency backup power requirements. Its robust construction and stable output make it suitable for critical facilities such as factories, offices, small commercial buildings, or standalone work sites needing reliable single-phase power.

Q: When should I perform regular maintenance on this generator?

A: It is recommended to conduct preventive maintenance every 250 hours of operation or as specified in the manufacturer's guidelines. Regular checks should include oil levels, coolant status, battery condition, and cleaning of air and fuel filters to ensure optimal performance and longevity.

Q: Where should the generator be installed for safe and effective operation?

A: Although the enclosure is weatherproof and soundproof, the generator should be installed on a stable, flat surface with adequate ventilation and access for maintenance. Outdoor installation is common, but always ensure the area is free from obstructions and stays within local compliance guidelines.

Q: What is the process for starting the generator?

A: This generator features an electric start system for user-friendly operation. Upon power failure, the AMF panel automatically initiates the start process. If starting manually, simply use the control panel to energize the system, ensuring all safety checks are observed before operation.

Q: How much diesel does the generator consume at full load?

A: At full load, the 30 KVA single-phase generator consumes approximately 6-7 litres of diesel fuel per hour. The 60-litre tank provides adequate autonomy for extended backup periods, depending on your load requirements.

Q: What are the main benefits of the weather and soundproof acoustic enclosure?

A: The weather and soundproof acoustic enclosure protects the generator from rain, dust, and environmental extremes while significantly minimizing operational noise. This allows for quieter, longer-lasting performance suitable for sensitive environments or locations where noise regulation is critical.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Diesel Generator Set Category

CPCB IV Plus Genset

CPCB IV Plus Genset

Minimum Order Quantity : 1 Unit

Output Type : AC Three Phase

Engine Model : Engine CPCBIV+

Protection Class : IP 23

Cooling System : Water Cooled

Fuel Consumption : 8.1 ltr/hr at 100% load

Generator Set

Generator Set

Minimum Order Quantity : 1 Unit

Output Type : AC Three Phase

Engine Model : Kirloskar / Equivalent

Protection Class : IP23

Cooling System : Water Cooled

Fuel Consumption : 3.5 L/hr (at 100% load) Liter/Hour (L/hr)

Silent DG Set

Silent DG Set

Minimum Order Quantity : 1 Unit

Output Type : AC Three Phase

Engine Model : 6BT5.9G1

Protection Class : IP23

Cooling System : Water Cooled

Fuel Consumption : 13.5 L/hr (at 100% load)

DG Set

DG Set

Minimum Order Quantity : 1 Unit

Output Type : AC Single/Three Phase

Engine Model : Kirloskar 3R1040

Protection Class : IP23

Cooling System : Water Cooled

Fuel Consumption : 4.5 Ltr/hr (at 75% Load)



Back to top